{"id":661,"date":"2024-06-14T16:15:07","date_gmt":"2024-06-14T08:15:07","guid":{"rendered":"http:\/\/enerlution.cn\/?p=661"},"modified":"2024-07-01T15:44:49","modified_gmt":"2024-07-01T07:44:49","slug":"hy1mw-bess","status":"publish","type":"post","link":"https:\/\/www.enerlution.cn\/en\/2024\/06\/14\/hy1mw-bess\/","title":{"rendered":"HY1MW-BESS"},"content":{"rendered":"<div class=\"wp-block-getwid-tabs\" data-active-tab=\"0\"><ul class=\"wp-block-getwid-tabs__nav-links\"><\/ul>\n<div class=\"wp-block-getwid-tabs__nav-link\"><span class=\"wp-block-getwid-tabs__title-wrapper\"><a href=\"#\"><span class=\"wp-block-getwid-tabs__title\">Product Details<\/span><\/a><\/span><\/div><div class=\"wp-block-getwid-tabs__tab-content-wrapper\"><div class=\"wp-block-getwid-tabs__tab-content\">\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>model<\/strong><\/td><td><strong>HY556K-BESS<\/strong><\/td><td><strong>HY2782K-BESS<\/strong><\/td><\/tr><tr><td><strong>PV parameters<\/strong><\/td><td><\/td><td><\/td><\/tr><tr><td>Maximum photovoltaic input voltage<\/td><td>1500V<\/td><td>1500V<\/td><\/tr><tr><td>MPPT voltage range at nominal power<\/td><td>860~1250V<\/td><td>860~1300V<\/td><\/tr><tr><td>Number of DC inputs<\/td><td>5<\/td><td>24<\/td><\/tr><tr><td>Maximum PV input current<\/td><td>1250A<\/td><td>5228A<\/td><\/tr><tr><td><strong>DC parameters<\/strong><\/td><td><\/td><td><\/td><\/tr><tr><td>Operating voltage range<\/td><td>500~1500V<\/td><td>500~1500V<\/td><\/tr><tr><td>Nominal power<\/td><td>250kw<\/td><td>250kw*5<\/td><\/tr><tr><td>Maximum current<\/td><td>344A<\/td><td>344A*5<\/td><\/tr><tr><td><strong>Battery parameters<\/strong><\/td><td><\/td><td><\/td><\/tr><tr><td>Cell Type<\/td><td>38.4V\/100Ah<\/td><td>38.4V\/100Ah<\/td><\/tr><tr><td>System Configuration<\/td><td>2P252S*3<\/td><td>252S30P<\/td><\/tr><tr><td>Battery capacity (BOL)<\/td><td>556kWh<\/td><td>2782kWh<\/td><\/tr><tr><td>Battery voltage range<\/td><td>806.4~1045.8V<\/td><td><\/td><\/tr><tr><td><strong>AC parameters<\/strong><\/td><td><\/td><td><\/td><\/tr><tr><td>AC output power<\/td><td>500kVA@50\u2103<\/td><td>2750kVA@45\u2103(113\u2109)\/2500kVA@50\u2103(122\u2109)<\/td><\/tr><tr><td>Maximum AC output current<\/td><td>480A<\/td><td>2886A<\/td><\/tr><tr><td>Nominal AC voltage<\/td><td>3\/PE,600V<\/td><td>550V<\/td><\/tr><tr><td>AC voltage range<\/td><td>480~690V<\/td><td>484~605V<\/td><\/tr><tr><td>Nominal grid frequency<br>\/Grid frequency range<\/td><td>60Hz\/55~65Hz<\/td><td>60Hz\/55~65Hz<\/td><\/tr><tr><td>Voltage standard<\/td><td>Three-phase three-wire<\/td><td>Three-phase three-wire<\/td><\/tr><tr><td><strong>Other parameters<\/strong><\/td><td><\/td><td><\/td><\/tr><tr><td>size<\/td><td>6058*2896*2438mm<\/td><td>12192*2896*2438mm<\/td><\/tr><tr><td>weight<\/td><td>11.0T<\/td><td>37T<\/td><\/tr><tr><td>Protection level<\/td><td>IP54<\/td><td>IP54<\/td><\/tr><tr><td>range of working temperature<\/td><td>-30\u2103~50\u2103<\/td><td>-30\u2103~50\u2103<\/td><\/tr><tr><td>Relative humidity<\/td><td>0~95% (no condensation)<\/td><td>0~95% (no condensation)<\/td><\/tr><tr><td>Maximum operating altitude<\/td><td>2000m<\/td><td>2000m<\/td><\/tr><tr><td>Battery compartment cooling method<\/td><td>Intelligent temperature control<\/td><td>Intelligent temperature control<\/td><\/tr><tr><td>Battery compartment fire protection<\/td><td>FM-200 Fire Extinguishing System<\/td><td>FM-200 Fire Extinguishing System<\/td><\/tr><tr><td>Communication Interface<\/td><td>RS485, Ethernet<\/td><td>RS485, Ethernet<\/td><\/tr><tr><td>Protocol<\/td><td>Modbus RTU, Modus TCP<\/td><td>Modbus RTU, Modus TCP<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Containerized Energy Storage System<\/strong><strong><\/strong><\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">The container energy storage system includes: energy storage battery system, boost system, fire protection system, monitoring system, etc., which are widely used in power safety, backup power supply, peak load reduction and valley filling and other fields.<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>low cost<\/strong><strong><\/strong><\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">* ESS is highly integrated, convenient for transportation and operation and maintenance<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">* Al pre-assembled, no need to handle battery modules on site<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">* 8 hours installation and commissioning<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Safe and reliable<\/strong><strong><\/strong><\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">* DC circuit safety management including quick disconnection and arc protection<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">* Multi-level battery protection layer formed by independent systems<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Efficient and flexible<\/strong><strong><\/strong><\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">* Intelligent liquid cooling ensures higher efficiency and longer battery cycle life<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">* Modular design supports parallel connection and easy system expansion<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">* IP55 outdoor cabinet<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>intelligent<\/strong><strong>change<\/strong><strong><\/strong><\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">* Rapid status monitoring and fault recording to realize alarm and fault location<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">* Integrated battery performance monitoring and logging<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n<\/div><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[13],"tags":[],"class_list":["post-661","post","type-post","status-publish","format-standard","hentry","category-13"],"_links":{"self":[{"href":"https:\/\/www.enerlution.cn\/en\/wp-json\/wp\/v2\/posts\/661","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.enerlution.cn\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.enerlution.cn\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.enerlution.cn\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.enerlution.cn\/en\/wp-json\/wp\/v2\/comments?post=661"}],"version-history":[{"count":1,"href":"https:\/\/www.enerlution.cn\/en\/wp-json\/wp\/v2\/posts\/661\/revisions"}],"predecessor-version":[{"id":665,"href":"https:\/\/www.enerlution.cn\/en\/wp-json\/wp\/v2\/posts\/661\/revisions\/665"}],"wp:attachment":[{"href":"https:\/\/www.enerlution.cn\/en\/wp-json\/wp\/v2\/media?parent=661"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.enerlution.cn\/en\/wp-json\/wp\/v2\/categories?post=661"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.enerlution.cn\/en\/wp-json\/wp\/v2\/tags?post=661"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}